Industry data shows that 35% of ultrasonic cleaner failures are caused by incorrect wiring (Source: Ultrasonic Technology Journal, 2023). Key risks include:
| Parameter | Typical Value | Your Model |
|---|---|---|
| Voltage | 110V/220V | [ ] |
| Frequency | 50/60Hz | [ ] |
| Power Rating | 100W-1500W | [ ] |
| Current Draw | 1A-15A | [ ] |
Step 1: Identify Terminal Blocks
Locate these critical points (refer to your manual):
Step 2: Power Cable Connection
复制
[Correct Wiring Sequence] 1. Strip cable ends (8-10mm) 2. Connect: • Brown wire → L terminal • Blue wire → N terminal • Green/yellow → PE terminal 3. Torque screws to 0.5Nm
Step 3: Transducer Wiring
Step 4: Control Panel Wiring
| Wire Color | Function | Connection Point |
|---|---|---|
| Red | Timer control | T1 |
| Black | Heater | H+ |
| White | Power LED | L1 |
Step 5: Final Checks
Mistake 1: Reversed Polarity
Mistake 2: Loose Grounding
Mistake 3: Over-tightened Terminals
Mistake 4: Incorrect Wire Gauge
Option 1: External Timer Wiring
复制
[Connection Diagram]
Cleaner ──┬── Timer (NO contact)
└── Power source
Option 2: Multi-Unit Parallel Connection
| Problem | Possible Cause | Test Method |
|---|---|---|
| No power | Blown fuse | Continuity test |
| Weak cleaning | Low voltage | Multimeter check |
| Tripping breaker | Short circuit | Megger test |
| Task | Frequency | Tools Needed |
|---|---|---|
| Terminal inspection | Monthly | Torque wrench |
| Ground resistance test | Quarterly | Earth tester |
| Full rewiring | Every 5 years | - |
Technical Data:
Always consult a licensed electrician for installations in commercial/industrial settings. Following this guide can prevent 80% of electrical failures in ultrasonic cleaning systems.