Knowledge | 2022-10-10

Points for attention in the use of a small ultrasonic cleaning machine

Return


Small ultrasonic cleaning machine usually refers to a cleaning capacity is 3l below the cleaning machine, to commercial, laboratory, and home-based. Small ultrasonic cleaning machine is characterized by small, due to small size, design more precise and meticulous, but not the correct use is more likely to damage the cleaning machine.


Points to note when using small ultrasonic cleaning machines are as follows:


1, to avoid the cleaning tank, because of the heat expansion and cold contraction of the transducer off, so can not be overheated cleaning fluid suddenly poured into the cleaning cylinder.

2, the correct choice of cleaning agent, cleaning effect is very important, according to the need to clean the surface of the objects attached, to determine the cleaning agent. There are Oil removers, Rust removers, paint removers, carbon removers, wax removers, and other organic chemical cleaning agents. Can not contain strong acid, or strong alkali solution in the cleaning tank, to corrosion cleaning tank.

3. In the process of working, the ultrasonic cleaning machine can make the liquid produce a certain temperature, make the liquid temperature that the liquid produces, the summer is generally stable at about 55 ° C, and the winter is about 45 ° C. If the choice of solvent cleaning, one must pay attention to understand the temperature of the burning point of the solvent. If using flammable solvent cleaning, should pay attention to the temperature changes in the cleaning tank, if the liquid temperature is too high, should turn off the ultrasonic power, and wait for the solvent temperature to drop after cleaning, to ensure safety, if the use of flammable solvent cleaning“Can not heat”, otherwise it may catch fire.

4. Put the objects that need to be cleaned into the cleaning basket or on the special fixture. The cleaning objects will have a better cleaning effect if they do not come into contact with the tank body.

5. The heater is installed at the position below 2/3 of the back of the inner groove. When heating, do not touch the position of the heating plate with your hands. Be careful of scalding. Do not heat the heater when the liquid level is below 2/3 of the height of the inner groove, it is suggested that the ultrasonic cleaning machine should not be heated to over 80 ° C for a long time, which will shorten the service life of the ultrasonic cleaning machine.


Summary: even the best equipment needs to be operated in the right way. The instruction manual for the equipment is a very good thing. It can solve most of the routine problems in the use process, I hope you read it before the operation.

Points for attention in the use of a small ultrasonic cleaning machine